Photovoltaics (PV / FVE)
Business, municipal and HOA installations — rooftop and ground-mounted. Data-driven sizing, design, delivery, grid connection and inspections.
PV (FVE) detailsIndustrial energy
Solutions for businesses, municipalities & HOAs
We deliver integrated energy solutions for real operations: PV (FVE), battery storage (BESS), smart control (EMS/SCADA) and e-mobility with DLM — including design, grid connection and inspections plus service monitoring.
Built on solid foundations in electrical engineering and inspections.
We build solutions that are connectable, safe and controllable. Every pillar comes with clear outputs, documentation and operational continuity (metering, protections, EMS/SCADA).
Business, municipal and HOA installations — rooftop and ground-mounted. Data-driven sizing, design, delivery, grid connection and inspections.
PV (FVE) detailsStorage from kWh to MWh: peak-shaving, backup, demand stabilization, EMS integration. Safety design, protections, commissioning and service regime by criticality.
BESS detailsThe “brain”: power control, connection limits, zero export, self-consumption optimization and reporting. Without EMS you have a source; with EMS you have a system.
EMS/SCADA detailsPreparing resources (often BESS) for flexibility. We deliver metering, communication, control logic and operating modes.
Aggregation detailsTechnical support for RES+/OPTAK and documentation inputs (reports, parameters, designs). Goal: a smooth process without unnecessary returns.
Subsidy supportCharging infrastructure for businesses and municipalities. Dynamic load management (DLM), RFID, billing, load management and future expansion readiness.
E-mobility detailsEnd-to-end PV delivery — from business case and permits to service and monitoring.
System sizing based on consumption, self-consumption scenarios, export limitations, and a high-level project business case.
Grid-connection documentation, coordination with the distribution operator, contractual/process steps, and guidance through available grant options.
Engineering support, documentation, coordination, and guidance to keep approvals moving without unnecessary delays.
Rooftop and ground-mounted installations to design, safe cable routing, H&S compliance, quality workmanship, and a clean handover.
Preventive inspections, repairs, SLA, performance-drop diagnostics, and fast response based on operational criticality.
Monitoring access, alerts, reporting, and practical operator training for reliable day-to-day operation.
Energy isn’t about “buying technology”. It’s about controlling power, costs and risk based on your data and connection limits. Here are typical scenarios.
BESS + EMS trims demand peaks. It relieves the grid connection and typically reduces pressure to increase the main breaker.
Backup mode during outages for servers, cooling, production or security technologies.
Where export is not permitted, we implement limitation and control logic so production is maximally used for self-consumption.
Accurate data on generation, consumption, CO₂ savings and states — ready for internal reporting, audit and financing.
Battery charge/discharge and consumption control based on operating rules and price signals (where meaningful).
Chargers with dynamic load management: vehicles charge with available power but do not overload the connection or site operation.
Business energy is more than panels. It’s switchboards, protections, communications, metering and control. Good execution reduces future service cost.
Consumption profile, grid limits, operating goals. Concept proposal (PV/BESS/EMS/DLM) and initial economics.
Design documentation (scope-based), trade coordination, connection documents, subsidy support and timeline.
Installation, switchboards, protections, communications, metering. Limit settings, testing and go-live.
Initial inspection, handover documentation, monitoring and service supervision. Long-term stable operation.
We deliver nationwide — decisions are driven by data, grid connection, safety and operating goals. Typical clients: industrial sites, logistics, warehouses, public buildings and HOAs.
Outside these areas? No problem — we can handle concept and delivery nationwide. Send us your data and goals; we’ll propose next steps.
Long-term partnerships with top companies in industry and the public sector.
It’s not just installing hardware — it’s a controllable system: PV (FVE) generates, the battery (BESS) stores, and EMS/SCADA controls power according to grid-connection limits, consumption and operating rules. The result is stable operation, higher self-consumption, export control and predictable site behavior.
Typically where there is stable daytime consumption, weekday operation, or where production can be used intentionally (technology, cooling, manufacturing, charging). Key factors are sizing based on your data, grid-connection limits and realistic scenarios (self-consumption, battery, power control, and possibly aggregation).
We start with the consumption profile (15-minute data, billing, operating regime), roof/land assessment, grid-connection options and goals (savings, zero export, peak-shaving, ESG). We usually deliver options so you can see how PV size, battery and control affect economics and operation.
BESS is a battery system (kWh–MWh) that stores energy and helps manage peaks, stabilize demand, increase PV self-consumption, or back up selected circuits. In companies, it often pays off mainly through peak-shaving and power control (to avoid exceeding connection limits).
Peak-shaving means BESS + EMS covers short demand spikes that would otherwise load the connection. In practice, it reduces the risk of exceeding limits, improves operational stability and — in some scenarios — provides inputs for optimizing reserved capacity, always based on your data and distributor conditions.
EMS/SCADA is the control layer that decides when to generate, store, curtail output, charge/discharge the battery and how to enforce grid limits. In B2B, the difference between a “source” and a “system” is control: without EMS you often lose part of the benefits and increase operational risk.
Yes. Where export is not allowed or is limited, we implement technical power limitation and EMS control logic so self-consumption is maximized and the system behaves stably without unnecessary oscillations.
We prepare technical documents for connection, coordinate communication with the distributor, deliver design documentation and electrical dependencies (switchboards, protections, metering). The goal is a connectable design with clear steps to commissioning.
Yes. For business and municipal projects, we typically deliver design documentation (scope-based), engineering, coordination and commissioning (tests, limit settings, communication verification and operating modes). Handover documentation is included so the system remains manageable long-term.
Yes. We treat inspections and measurements as part of safe handover: initial inspections per scope, protocols, circuit labeling and operating recommendations. For BESS/EMS, traceable documentation is also crucial for service and audits.
Safety is addressed through architecture, protections, fusing, measurement, ventilation/placement per design and clear operating modes. We emphasize service access, diagnostics and monitoring so issues are detected early and intervention is fast and controlled.
Yes. We deliver online supervision (generation/consumption/states), alarms for faults or deviations and data exports for reporting. For business projects, this often supports auditability and long-term benefit evaluation.
Flexibility means the ability of a resource (often BESS) to change power in a controlled way based on operational needs and market/aggregator signals. It pays off where technical capabilities, operational limits and economics align. We prepare measurement, communications and control logic so the resource is technically ready for flexibility.
DLM allows charging more vehicles without overloading the grid connection or disrupting site operation. It distributes available power based on rules (priorities, time, tariffs), can integrate with PV/BESS, and prepares infrastructure for future expansion.
Ideally 15-minute consumption data (or at least billing and operating regime), information about the connection/main breaker, your goal (savings, zero export, backup, peak-shaving, charging), and a few photos/plans of the roof or technology. The rest is completed during the technical survey and measurement.