Protection for the building and the technology inside
We don’t do “just a wire on the roof”. We align LPS with grounding, bonding and surge protection.
Installation, repairs and inspections of lightning protection systems (LPS) and surge protection (SPD) for companies, municipalities, schools and apartment buildings. We ensure continuity across grounding and bonding so the protection works as one system — no improvisation, with protocols suitable for audits and insurance.
Safety
correct joints & continuity
Protocols
inspections • audits • insurance
Primarily Ostrava & Moravian-Silesian Region. Nationwide for larger projects.
We don’t do “just a wire on the roof”. We align LPS with grounding, bonding and surge protection.
Clear deliverables, labeling and handover that make sense for facility management and auditors.
Clean routing, correct connection details and access for future inspections and repairs.
After a lightning strike or fault we diagnose, repair and return the system to a safe state.
Lightning and surge risks are often “silent” until something breaks. We set up protection that is functional, traceable and serviceable.
Halls, warehouses, switchboards and sensitive equipment—focus on operational continuity and minimal downtime.
Offices, operations and logistics—protect IT, validate measurements, and link to electrical inspections and documentation.
Solutions that hold up in real operation and inspections—safety, traceability and clean handover.
Repairs and modernization of older LPS, adding surge protection and verifying the grounding electrode.
Best value comes from a complete system: LPS, SPD, grounding and bonding. This reduces damage, downtime and “unknowns” during inspections.
Design and installation of external lightning protection: air terminals, down conductors, grounding, correct connection details and labeling.
Older systems often suffer from corrosion, loose joints or unclear bonding. We bring order and service logic.
Verification of installation quality, joints and system continuity. Clear reports and recommendations for safe operation.
Internal protection against overvoltage—protects switchboards, electronics, IT and technology from storms and switching events.
Without good grounding, neither LPS nor SPD will work well. We solve it as one system.
If an incident happens: we check the system, diagnose damage, propose repairs and steps to reduce repeat risk.
Older buildings often have LPS without clear grounding continuity, missing bonding or missing surge protection. We treat these parts together— that’s where the real benefit comes from.
Clear scope, clean protocols and practical recommendations. Not “it’s done somehow”—but serviceable protection you can operate long-term.
If surge protection requires switchboard adjustments, we deliver a clean, safe and serviceable setup.
If inspection uncovers issues in the installation, we can implement the necessary wiring/protection corrections.
Initial and periodic inspections, protocols, recommendations and service steps for safe operation.
We tailor the approach to whether you need an inspection, a repair, or a full new installation—always around safety and site operations.
Tell us what you need (inspection, repair, new LPS, SPD). We agree on a site visit and required inputs.
We map the LPS condition, critical joints, grounding continuity and switchboard situation. For industrial sites we also plan outages.
You get a clear plan: what to fix now, what to modernize, and how to strengthen protection (SPD, bonding).
We install and modify with focus on safety, serviceability and clean routing.
We hand over protocols, recommendations and documentation. For larger sites we can set periodic inspection plans.
Long-term partnerships with top companies in industry and the public sector.
Yes. We build new lightning protection systems (LPS) and repair/modernize existing ones. We also verify grounding and bonding continuity so the system works as a whole.
LPS (external protection) safely conducts lightning current into the ground. SPD (surge protection) protects internal wiring and electronics from overvoltages caused by storms and switching events. The best outcome is when both are correctly coordinated.
Yes—initial and periodic inspections depending on the building type and operational requirements. Output is a clear report and recommended improvements to reduce faults and damage risk.
Typical signs include corrosion, loose joints, damaged fixings, missing parts, unclear routing, or improvised add-ons. Often issues are discovered during inspection or after an incident.
Yes. We assess the installation and switchboards, recommend suitable SPD and implement changes so the protection is functional and serviceable.
Yes. Grounding quality and bonding continuity are crucial for both LPS and SPD. We check it and recommend repairs or additions where needed.
In most cases, yes. We stage work and plan it around site safety and operations. Outages are required only where truly necessary (e.g., switchboard work).
That’s fine. We perform an on-site survey and map the actual state. We then deliver outputs so facility management and future inspections have a clear baseline.
Yes. We inspect the LPS and critical joints, check SPD and switchboards, and propose repairs plus preventive steps to reduce repeat risk.
Industrial and technology sites, public buildings, companies with IT and sensitive electronics, apartment buildings, and sites in exposed locations—where preventive protection has the highest value.
Yes. For lightning protection we often address main equipotential bonding and grounding continuity. That prevents “blind spots” and keeps the system safe and serviceable long-term.
Building type, location, a short description (inspection / repair / new LPS / SPD) and ideally photos of roof components, down conductors and switchboards. The exact scope is confirmed during the site visit.